Currently browsing: Electrical Cleaner

ISO PROPYL ALCOHOL IPA

 

 PRODUCT NAME  

:

ISOPROPYLALCOHOL

 CAS number   

:

67-63-0

 UN number     

:

1219

 Formula     

:

(CH3)2CHOH

 Odour    

:

SHARP, SOMEWHAT UN PLEASANT

 Solubility in water   

:

COMPLETE

 Density    

:

0.783   at 20 oC

 Boiling point 

:

82 oC

 Melting point    

:

-90 oC

 Viscosity  

:

2.86 cp at 15 oC

 Flashpoint   

…..

Read more

Degreaser Electrical Non Flame

For Spray Method :::

Electrical Cleaner & Degreaser generously on surfaces that require cleaning. 

Brush or agitate if necessary 

Leave to dry.

For stubborn grease, manual agitation with a brush or cloth may be required.

For DIP METHOD :::

Shake well before use.

Pour the product into a metal container

Soak parts to be cleaned into Safety Electrical Cleaner & Degreaser for about 5 to 15 minutes

Brush or agitate if necessary. 

For parts with stubborn grime or slud…..

Read more

Methylene Chloride

Methylene Chloride National and International supplier in INDIA and UAE.  We deal in fully tested and specified all types of CHLORINATED SOLVENT like Methylene Chloride, Perchloro Ethylene and Trichloroethylene, CPW. 
Methylene Chloride is a colourless, neutral liquid heavier than water and It is completely miscible with almost all organic solvents but only sparingly with water. It has excellent solvency power to most organic chemicals and materials.  …..

Read more

Electrosol Plus Low Evaporation Rate

Characteristics ;

High dissolving and penetration action.

Excellent degreasing and emulsification power .

Safe on applied electrical insulation.

Non-corrosive .It is safe to use on painted or varnished metal surfaces.

Without chlorinated solvents.

To be used as an alternative to conventional electric cleaners               

Classification:

Description

Concentration

Product no.

ELECTROSOL – PLUS

95 – 98 % 

RXSOL-16-1077-025

E…..

Read more

Electrosol QD electroclean

RXSOL brand electrical cleaner have various type based on uses and application of electrical parts cleaning action. And we are holding as Electrosol QD electroclean manufacturer and exprter class. And our company have Electrosol QD electroclean supply network in Navi Mumbai, Mumbai, Rabale, Surat, Gandhidham, Kandla, Ennore, Chennai, Visakhapatnam, Vizag, Kakinada, Manglore, Goa, Nashik, Pune, Kolkata, Haldia, Paradip. Fujairah, Sharjah, Dubai, Abudhabi, Uae, Middle East……

Read more

Electrosol Quick Dry 25 Ltr

CLASSIFICATION : * ELECTROSOL QD (quick dry ) *ELECTROSOL NF (Non-flammable ) *ELECTROSOL PLUS APPLICATION : For cleaning of electrical parts .
Electrical Contact Cleaner manufacturers, Electrical Contact Cleaner suppliers, Electrical Contact Cleaner producers, Electrical Contact Cleaner exporters, Electrical Contact Cleaner production unit at mumbai, kandla, Visakhapatnam, tuticorin, chennai, ennore, surat, kolkata, haldia, dubai, fujairah……

Read more

Electrosol Quick Dry 30 Kg

It must be applied concentrated .
RXSOL-16-1009-025 is also fast evaporating leaving no residue. RXSOL-16-1009-025 is ideal for use on electric motors, plant machinery, elevator shafts and motors, generators, condensers, coils, etc.
RXSOL-16-1009-025  is safe to use on metal or rubber surfaces. reduces fire hazards caused by defective electric motors: RXSOL-16-1009-025 rapidly breaks down oils,and waxes. RXSOL-1009 can also be used to remove oil and stains from material.
(TEST A SMALL AREA …..

Read more

Acetone Pure ( CH3)2CO-I

 

 

ITEM

:

ACETONE ( CH3)2CO

DATE OF TEST

:

24.1.2013

SPECIFICATION OF PRODUCT

 

 

MIN ASSAY

:

99.5

BOILING POINT

:

56.1

IDENTITY

:

By IR  SPECTRUM

Wt. PER ML AT 20OC

:

0.791g

WATER CONTENT, WT. % MAX

:

0.01%

COLOUR

:

10 HAZEN UNITS

CARBONISABLE SUBST…..

Read more

Air Cooler Cleaner ACC-009

3 to 5 litres of cleaning solution per square meter or as table below:

Engine HP.

Solution of 10 to 25% RXSOL-16-1049-020

6,000 to 12,000

2 to 3 litre

12,000 to 24,000

4 to 5 litre

24,000 or  more

6 litre

NOTE :
For cleaning of Air cooler and Air side of  turbochargers, a  solution  of  5 – 25% RXSOL-16-0009-ACC in fresh  water is recommended. Inject the solution for 10-15minutes, then similar quantity of fresh water injected to rinse off em…..

Read more

Aqua Break RX 20 Ltr

WHY RXSOL-16-3003-020 is better ?

An economical  highly concentrated product.
Compatible with oily water separators.
Releasing the oil phase for reclamation.
Suitable for all types of floors. Deodorizing nature.
Eliminates the need to buy & stock duplicate products because of its effectiveness.
Also used for gas and hydrocarbon freeing of tanks. Free from caustic & hydrcarbon, Non flammable Water based, Biodegradable. Safe to metal
 …..

Read more

Aqua Break RX 25 Ltrs

Method of Application and Doses:- 
1st of all by stripping suction removes all possible oil (greasy materials). To prevents evaporation of lighter fraction oil flush the system with cold water.May be brushed on, sprayed (Hand spray/Direct injection) recirculate  the system with RXSOL-16-3003-025 Solution

1.

Cleaning with   washing machines. Dose rate: 0.3-5 ltr per ton wash water (0.03-0.5%).     

2.

Cleaning with recirculation method. Dose rate: 0.5-10 ltr per ton wash water, (0.05-1…..

Read more

AQUA Tuff High Foam conc.

Cleaning agents used in Aquatuff  for hold cleaning solution is fully biodegradable and not be harmful to the marine.  Allow the Aquatuff High foam solution to act for 10-20 minutes thereafter wash the chemicals with high pressure. Due to compatibility and non hazardous nature of Aquatuff makes it superior all purpose cleaner for tank and cargo hold cleaning to essential maintenance tasks in the engine room, or general cleaning of crew and galley areas, every cleaning task.
Heavy Soil deposit…..

Read more

Hydrocarbon Remover Hcf

Using Procedure:-

First of all flush the system with cold water to prevent evaporation rates and polymerization then the most economical method of using RXSOL-20-2008-HCF is by direct injection followed by recirculation washing, using tank cleaning machines.

Spraying Method:- 

Using HCF as delivered in drums, spray onto areas where residue remains following rough washing leave for 10-45 minutes (but do not allow to dry), then butterworth at maximum pressure and warm water 60oC for at lea…..

Read more

Rocor NB Liquid With Indicator 25 Ltr

…..

Read more

Slip Coat RXSOL HOLD BLOCK 25 Ltr

…..

Read more

Bentonite Powder

Bentonite can be Broadely classified in 2 grades :
 
Granular: Granular is the preferred option for filling trenches where the conductor is covered with Bentonite and then water poured over and mixed in the trench.
 
Powder: Powder is the preferred method for pouring into bore holes to en-sure the mixture is of a thin enough consistency to reach the bottom of the bore hole. If diamond drilling is required for deep holes, possible 40m depths and deeper and the Bentonite is to be pumped throug…..

Read more